100 V line wiring lets many speakers share one amplifier channel over long cable runs: each speaker has a transformer with power taps, and the amplifier needs enough power for the sum of the taps, plus headroom. If the system must also carry evacuation messages, the speakers usually need EN 54-24 certification and the whole system must meet the fire and life safety design.

1. Low Impedance or 100 V?

A low impedance system connects a few speakers (4 or 8 ohm) directly to each amplifier channel. It gives the best sound for a stage, a hall or a premium restaurant. A 100 V system adds a transformer to each speaker so that dozens of speakers, spread across corridors, offices, car parks and gardens, run from one amplifier channel on thin cable. Many installed speakers offer both: the Fohhn AT-10 is an 8 ohm speaker with an optional 100 V transformer rated at 120 W, and the Fohhn AT-35 has a 240 W option.

2. How to Size a 100 V Line

  1. Pick a tap for each speaker from the level that area needs. Quiet offices need a low tap; noisy kitchens, car parks and plant rooms need more.
  2. Add up the taps on each line.
  3. Leave headroom, often about 20 percent, so the amplifier is never driven to its limit.
  4. Check the cable: long runs lose power in the cable, so larger loads and longer runs need thicker cable.

The tap impedance and power are linked by the line voltage: power equals 100 squared divided by the impedance. The Fohhn LEN-100 shows this on its data sheet: its S transformer gives 80 W at 125 ohm and its M transformer gives 160 W at 63 ohm, with 50 percent and 25 percent taps as well.

3. EN 54-24: Speakers for Voice Alarm

When announcements are part of the fire alarm and evacuation system, the speakers must meet EN 54-24. Certified speakers are tested for output, directivity, durability and how they behave in a fire, and are marked type A (indoor) or type B (indoor and outdoor). The rest of the system has its own standards, such as EN 54-16 for voice alarm control and indicating equipment.

Fohhn LEN model Drivers Dispersion Certification
Fohhn LEN-20 2 x 4 inch 130 x 60 degrees EN 54-24
Fohhn LEN-60 6 x 4 inch 130 x 25 degrees EN 54-24
Fohhn LEN-100 8 x 4 inch 130 x 15 degrees EN 54-24 type B, IP65
Fohhn LEN-150 12 x 4 inch 130 x 14 degrees EN 54-24
Fohhn LEN-220 18 x 4 inch 130 x 14 degrees EN 54-24

The LEN columns combine voice alarm certification with the narrow vertical coverage of a column, which keeps announcements intelligible in reverberant spaces such as atriums, terminals, malls and mosques.

4. Voice Alarm Is a Life Safety System

In the UAE the building's fire and life safety design and the Civil Defence approval decide whether a voice alarm system is needed and which certified products may be used. Always confirm the requirement with the fire consultant first. A voice alarm system also needs monitored lines, battery backup and a certified controller, so it is planned as one system rather than speaker by speaker.

Quick Checklist

Question What to check
Music quality or many speakers over long runs? Low impedance for quality, 100 V for distributed systems
Which tap for each area? The level needed and the background noise
Is the amplifier big enough? Sum of taps plus about 20 percent headroom
Are announcements part of the fire system? EN 54-24 speakers, certified controller, Civil Defence approval
Indoor or outdoor? EN 54-24 type A or type B, IP rating

Public Address and Voice Alarm in Dubai and Abu Dhabi

Trianze Tech supplies 100 V speakers, columns and amplifiers for offices, malls, hotels, schools and mosques across the UAE. See our public address and background music solutions, browse TOA, Fohhn and installation speakers, and read point source vs column vs beam steering speakers.

Call +971 58 161 3661 | Chat on WhatsApp

Frequently asked questions

What is a 100 V line speaker system?

A 100 V line system uses a transformer in each speaker so that many speakers can share one amplifier channel over long cables. Each speaker has power taps (for example 80 W, 40 W and 20 W), the installer picks a tap for the level needed in that area, and the amplifier only needs enough power for the sum of the taps. It is the standard way to wire public address, background music and voice alarm systems in buildings.

How many speakers can I put on one 100 V amplifier channel?

Add up the tap power of every speaker on the line and keep the total below the amplifier channel rating, with headroom (often about 20 percent). For example, 6 speakers on an 80 W tap make 480 W, so a 600 W channel such as one channel of the Fohhn MA-4.600 is enough. The tap impedance tells the same story: at 100 V an 80 W tap is 125 ohm.

What is the difference between 100 V and 70 V lines?

Both work the same way; only the line voltage at full power differs. 100 V lines are common in the UAE, Europe and Asia, while 70 V lines are common in North America. Speakers must have transformer taps for the line voltage in use, and many amplifiers, such as the Fohhn MA-4.600 and MA-2.1200, can drive 4 ohm, 70 V or 100 V lines.

What does EN 54-24 certification mean?

EN 54-24 is the European standard for loudspeakers used in voice alarm systems that are part of fire detection and alarm systems. Certified speakers are tested for sound output, directivity, durability and behaviour in fire conditions. Type A is for indoor use and type B for indoor and outdoor use; the Fohhn LEN-100, for example, is certified EN 54-24 type B and rated IP65.

Can I use any speaker for evacuation announcements?

No. Where the building's fire and life safety design calls for a voice alarm system, the speakers, amplifiers and controller must meet the required standards (such as EN 54-24 for speakers and EN 54-16 for voice alarm control equipment) and the authority's approval. In the UAE the fire consultant and Civil Defence requirements decide what is needed, so confirm with them before choosing speakers.

Where can I buy 100 V and EN 54-24 speakers in the UAE?

Trianze Tech supplies 100 V line speakers, EN 54-24 certified voice alarm speakers and amplifiers from Fohhn, TOA and other brands in Dubai and Abu Dhabi with delivery across the UAE and GCC. Call +971 58 161 3661 or message us on WhatsApp for the best price and current stock availability.